Generator excitation

P Bystrica TG3 3

Turbogenerator excitation

Turbogenerator excitation is implemented according to the type of excitation system as one of the following solutions: AVR Safety, AVR Power, or AVR Compact. The AVR Z110 regulator is designed as a single-board module and includes thyristor phase control, programmable logic devices (PLDs), two ARM-based microcontrollers, and communication adapters for USB, RS232, and Ethernet.

The regulator's control panel is integrated into the cabinet door along with a keypad. The panel features several types of screens that provide complete information on the status of the excitation system and the generator’s measured values. It also includes control buttons for local excitation operation. A similar control panel is available for installation in the unit control room.

The turbogenerator excitation control system can be extended with a generator synchronizer, implemented using the DSD Z110 module, which is also a single-board design and includes analog measurement inputs, programmable logic devices, two ARM-based microcontrollers, and communication adapters for USB, RS485/422, and Ethernet.

The AVR Safety excitation regulator complies with Category C safety functions according to ČSN EN 61226 and is implemented on the SandRA platform. It is communication-connected to the Unit Control and Information System (UCIS).

Diesel generator excitation

Diesel generator excitation is implemented using the AVR Safety system.

The diesel generator is intended for emergency power supply to the primary circuit of the nuclear power plant. The excitation system ensures precise regulation of the generator stator voltage and other parameters related to generator control by adjusting the excitation current.

The system performs Category A safety functions according to ČSN EN 61226. It is implemented on the SandRA Z110 platform. The regulator is communication-connected to the Unit Control and Information System (UCIS).

The diesel generator excitation control system, supplied by ZAT a.s., can be designed and implemented according to customer requirements, either as a complete system replacement or as a partial retrofit of the excitation control section.

02 Dukovany

Main functions of the voltage regulator:

  • Voltage and reactive power regulation
  • Voltage matching before synchronizing the generator to the grid
  • Zero reactive power setting before disconnecting the generator from the grid
  • Regulation of the excitation current during tests and loss of stator voltage measurement
  • Inverter operation of a thyristor rectifier for operational excitation of the generator
  • Stator and rotor current limiters
  • Voltage limiter and U/f limiter
  • Under-excitation limiter
  • System stabilizer
  • Generator phaser
  • PLC controller, fault diagnostics, and automatic switching between channels
Tabulka Buzení Regulátoru Buzení 2 EN

Function of the synchronization device:

Technology

Automatic closing of the generator circuit breaker

Technology

Monitoring and control of closing

Important references

  • Enguri Hydroelectric Power Plant

    Excitation system replacement – TG2

    Georgia, 2025

  • Hydroelectric Power Plant Štěchovice – TG3

    Excitation migration of TG3

    CZ, 2024

  • 10 excitation units at hydroelectric power plants – Slovakia

    Modernization of 10 excitation units

    Slovakia, 2024

  • Waterworks Žilina

    Reconstruction of excitation controllers TG1 and TG2

    SK, 2021

  • Empalme Thermal Power Plant I,II

    Delivery of 2 pieces of excitation generators 300 MW

    Mexico, 2019

  • Temelín Nuclear Power Plant

    Reconstruction of the I&C wastewater treatment plant, project B607

    CZ, 2019

  • Heating plant Katowice

    Reconstruction of turbine control system, reconstruction of 120 MW generator excitation

    Poland, 2017

  • Heating plant Písek

    Reconstruction of electrostatic precipitator source control - boilers K11 and K12

    CZ, 2016

  • Small hydroelectric power plant Střekov

    Modernization of excitation regulators TG1 to TG3

    CZ, 2016

  • Heating plant Strakonice

    K2 boiler control, new application software including visualization

    CZ, 2014

  • Thermal Power Plant Talkha

    Replacement of generator excitation, reconstruction of turbine control system

    Egypt, 2011